8-24 Troubleshooting
Beep Codes
If an error occurs during the POST, the server beeps, indicating the type of error.
Each number indicates the number of short beeps, and a hyphen indicates a pause. For example, the
beep interval 1-3-3-1 indicates 1 beep, a pause, 3 beeps, a pause, 3 beeps, a pause, and 1 beep,
which indicates that an error occurred while checking the memory capacity.
Beep code Description
Recommended action
1-3-3-1
No memory could be detected.
An error occurred during a
memory capacity check.
Make sure that the DIMMs are correctly inserted.
If this does not resolve the problem, contact your
service representative and request either DIMM
or motherboard replacement.
1-1
No graphics controller could be
detected.
Contact your service representative and request
motherboard replacement.
1
An error was detected during the
POST processing.
Contact your service representative and request
motherboard replacement.
1
DIMM has already been
installed.
3
Failed to read the BIOS
executable module. Or, BIOS
has no executable module.
4
Failed to initialize the BIOS
executable module.
7
Failed to reset the system.
Summary of Contents for N8100-1668F
Page 60: ...2 28 General Description This page is intentionally left blank ...
Page 146: ...5 8 Installing the Operating System with Express Setup Flow of Setup ...
Page 173: ...Installing the Operating System with Express Setup 5 35 Flow of Setup ...
Page 255: ...Installing and Using Utilities 6 13 Windows Server 2003 ...
Page 282: ...7 14 Maintenance This page is intentionally left blank ...
Page 339: ...Troubleshooting 8 57 When you use a remote console 6 Each tool is selected and it starts ...
Page 422: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Page 440: ...C 2 IRQ This page is intentionally left blank ...
Page 464: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete ...
Page 495: ...Installing Windows Server 2008 E 29 4 Activate Windows The Windows activation is complete ...
Page 558: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 568: ...I 10 Accessing Power and Performance Data This page is intentionally left blank ...
Page 572: ...J 4 Product Configuration Record Table This page is intentionally left blank ...