8-14 Troubleshooting
Displayed Error Message
Description
Recommended Action
8808
DXE_FLASH_UPDATE_FA
ILED
The Flash ROM was not written
to correctly.
Contact your service
representative.
8830
PEI_RECOVERY_NO_
CAPSULE
The Flash ROM was not
recovered correctly.
8831
PEI_RECOVERY_PPI_
NOT_FOUND
8832
PEI_RECOVERY_FAILED
9000
PEI_CPU_NO_MICROCO
DE
An unsupported CPU was
detected.
9001
Unsupported CPU detected
on CPU #1
9002
Unsupported CPU detected
on CPU #2
9021
Unsupported CPU Speed
detected on CPU #1
A CPU running at an
unsupported clock speed was
detected.
9022
Unsupported CPU Speed
detected on CPU #2
9040
PEI_CPU_SELF_TEST_
FAILED
An error was detected during
CPU initialization.
9060
PEI_CPU_MISMATCH
Different CPUs are installed for
CPU #1 and #2.
9800
GENERIC_CPU_THERMA
L_ERROR
A CPU temperature abnormality
was detected.
A001 Memory Error detected in
CPU1_DIMM1
An error was detected for
CPU1_DIMM1.
A002 Memory Error detected in
CPU1_DIMM2
An error was detected for
CPU1_DIMM2.
A003 Memory Error detected in
CPU1_DIMM3
An error was detected for
CPU1_DIMM3.
A004 Memory Error detected in
CPU1_DIMM4
An error was detected for
CPU1_DIMM4.
A005 Memory Error detected in
CPU1_DIMM5
An error was detected for
CPU1_DIMM5.
A006 Memory Error detected in
CPU1_DIMM6
An error was detected for
CPU1_DIMM6.
A007 Memory Error detected in
CPU2_DIMM1
An error was detected for
CPU2_DIMM1.
A008 Memory Error detected in
CPU2_DIMM2
An error was detected for
CPU2_DIMM2.
A009 Memory Error detected in
CPU2_DIMM3
An error was detected for
CPU2_DIMM3.
A00A Memory Error detected in
CPU2_DIMM4
An error was detected for
CPU2_DIMM4.
A00B Memory Error detected in
CPU2_DIMM5
An error was detected for
CPU2_DIMM5.
A00C Memory Error detected in
CPU2_DIMM6
An error was detected for
CPU2_DIMM6.
Summary of Contents for N8100-1668F
Page 60: ...2 28 General Description This page is intentionally left blank ...
Page 146: ...5 8 Installing the Operating System with Express Setup Flow of Setup ...
Page 173: ...Installing the Operating System with Express Setup 5 35 Flow of Setup ...
Page 255: ...Installing and Using Utilities 6 13 Windows Server 2003 ...
Page 282: ...7 14 Maintenance This page is intentionally left blank ...
Page 339: ...Troubleshooting 8 57 When you use a remote console 6 Each tool is selected and it starts ...
Page 422: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Page 440: ...C 2 IRQ This page is intentionally left blank ...
Page 464: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete ...
Page 495: ...Installing Windows Server 2008 E 29 4 Activate Windows The Windows activation is complete ...
Page 558: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 568: ...I 10 Accessing Power and Performance Data This page is intentionally left blank ...
Page 572: ...J 4 Product Configuration Record Table This page is intentionally left blank ...