8-16 Troubleshooting
Displayed Error Message
Description
Recommended Action
AE83 CPU1_DIMM3 with error
enabled.
CPU1_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
Contact your service
representative.
AE87 CPU2_DIMM1 with error
enabled.
CPU2_DIMM1 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
AE88 CPU2_DIMM2 with error
enabled.
CPU2_DIMM2 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
AE89 CPU2_DIMM3 with error
enabled.
CPU2_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
B000 DXE_LEGACY_OPROM_
NO_SPACE
There is no space for expanding
option ROM.
If the board is not used
as a boot device,
disable the Option
ROM Scan for that
board.
B001 Expansion ROM not
initialized - PCI Slot 1
Option ROM expansion in PCI
slot 1 failed.
B002 Expansion ROM not
initialized - PCI Slot 2
Option ROM expansion in PCI
slot 2 failed.
B003 Expansion ROM not
initialized - PCI Slot 3
Option ROM expansion in PCI
slot 3 failed.
B004 Expansion ROM not
initialized - PCI Slot 4
Option ROM expansion in PCI
slot 4 failed.
B005 Expansion ROM not
initialized - PCI Slot 5
Option ROM expansion in PCI
slot 5 failed.
B006 Expansion ROM not
initialized - PCI Slot 6
Option ROM expansion in PCI
slot 6 failed.
B030 PCI System Error on
Bus/Device/Function
PCI SERR was detected.
Contact your service
representative.
B040 PCI Parity Error on
Bus/Device/Function
PCI PERR was detected.
C010 The error occurred during
temperature sensor
reading
An error was detected while
reading the temperature sensor.
C011 System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan
has failed or is clogged
up. Contact your
service representative
and request repairs.
C020 The error occurred during
voltage sensor reading.
An error was detected while
reading the voltage sensor.
Contact your service
representative.
Summary of Contents for N8100-1668F
Page 60: ...2 28 General Description This page is intentionally left blank ...
Page 146: ...5 8 Installing the Operating System with Express Setup Flow of Setup ...
Page 173: ...Installing the Operating System with Express Setup 5 35 Flow of Setup ...
Page 255: ...Installing and Using Utilities 6 13 Windows Server 2003 ...
Page 282: ...7 14 Maintenance This page is intentionally left blank ...
Page 339: ...Troubleshooting 8 57 When you use a remote console 6 Each tool is selected and it starts ...
Page 422: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Page 440: ...C 2 IRQ This page is intentionally left blank ...
Page 464: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete ...
Page 495: ...Installing Windows Server 2008 E 29 4 Activate Windows The Windows activation is complete ...
Page 558: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 568: ...I 10 Accessing Power and Performance Data This page is intentionally left blank ...
Page 572: ...J 4 Product Configuration Record Table This page is intentionally left blank ...