Setting Up Your Server 3-17
NOTE:
When installing the server into NEC rack, fix the arm stopper
to the slide rail assembly with screw (B).
11.
Push the server into the rack once to check the installation position.
NOTE:
Make sure that the four screw holes at the upper left and right
sides on the front of the server are fit to the core nuts installed in step 2.
If the four positions are not fit at all, the slide rail assembly or the core
nuts may be installed incorrectly. If so, the adjacent units cannot be
installed without clearance. Confirm the installation positions and make
the reinstallation from the first step.
12.
Pull out or push the server into the rack for several times to confirm that the slides move
smoothly.
Push the arm stopper in the direction
shown by arrow mark so that the folded
portion hits the end.
Viewed from inside
Arm stopper