CHAPTER 20 RESET FUNCTION
User’s Manual U16899EJ2V0UD
394
Table 20-1. Hardware Statuses After Reset Acknowledgment (2/3)
Hardware
Status After Reset
Acknowledgment
Clock output/buzzer
output controller
Clock output selection register (CKS)
00H
Mode register (WDTM)
67H
Watchdog timer
Enable register (WDTE)
9AH
Conversion result register (ADCR)
Undefined
Mode register (ADM)
00H
Analog input channel specification register (ADS)
00H
Power-fail comparison mode register (PFM)
00H
A/D converter
Power-fail comparison threshold register (PFT)
00H
Receive buffer register 0 (RXB0)
FFH
Transmit shift register 0 (TXS0)
FFH
Asynchronous serial interface operation mode register 0 (ASIM0)
01H
Serial interface UART0
Baud rate generator control register 0 (BRGC0)
1FH
Receive buffer register 6 (RXB6)
FFH
Transmit buffer register 6 (TXB6)
FFH
Asynchronous serial interface operation mode register 6 (ASIM6)
01H
Asynchronous serial interface reception error status register 6 (ASIS6)
00H
Asynchronous serial interface transmission status register 6 (ASIF6)
00H
Clock selection register 6 (CKSR6)
00H
Baud rate generator control register 6 (BRGC6)
FFH
Serial interface UART6
Asynchronous serial interface control register 6 (ASICL6)
16H
Transmit buffer registers 10, 11 (SOTB10, SOTB11)
Undefined
Serial I/O shift registers 10, 11 (SIO10, SIO11)
Undefined
Serial operation mode registers 10, 11 (CSIM10, CSIM11)
00H
Serial interfaces CSI10,
CSI11
Note
Serial clock selection registers 10, 11 (CSIC10, CSIC11)
00H
Remainder data register 0 (SDR0)
0000H
Multiplication/division data register A0 (MDA0H, MDA0L)
0000H
Multiplication/division data register B0 (MDB0)
0000H
Multiplier/divider
Multiplier/divider control register 0 (DMUC0)
00H
Key interrupt
Key return mode register (KRM)
00H
Clock monitor
Mode register (CLM)
00H
Note Serial interface CSI11 is available only for the
µ
PD78F0133H, 78F0134H, 78F0136H, 78F0138H, and
78F0138HD.