background image

This document describes the following products:

■ Modular E70  Servo controller  SGS sensor 

Modular E70 Series Piezo Controller

User Manual

Version: V1.0

Summary of Contents for Modular E70 Series

Page 1: ...This document describes the following products Modular E70 Servo controller SGS sensor Modular E70 Series Piezo Controller User Manual Version V1 0 ...

Page 2: ...should be cleared to zero before turning off the controller switch such as switching the servo state to the open loop state Danger The piezoelectric power amplifier described in this manual is a high voltage device capable of outputting high currents which can cause serious or even fatal damage if not used properly It is strongly recommended that you do not touch any parts that connect to the high...

Page 3: ...nstallation Precautions 6 4 2 Ensure ventilation 6 4 3 Connect power 7 4 4 Cable connection 7 5 Parameter 7 5 1 Environmental Conditions 7 5 2 Drawings 8 5 3 Driving Principle 9 6 Power Calculation 9 7 Maintenance Storage Transportation 10 7 1 Cleaning measures 10 7 2 Transportation and Storage 10 8 Service and Maintenance 11 8 1 Disposal 11 8 2After sales Service 11 9 Contact us 12 ...

Page 4: ...installation and operation of it Please read the user manual in detail Please immediately eliminate any malfunctions and safety hazards caused by malfunctions If the protective grounding wire is not connected or connected incorrectly there will be possibility of electric leakage If you touch Modular E70 piezo controller it can cause serious or even fatal injuries If open Modular E70 privately touc...

Page 5: ...and understood the contents of the user manual before installing and operating the Modular E70 series piezo controller Only authorized professionals who meet the technical requirements can install operate maintain and clean the Modular E70 series of digital piezo controllers 2 Features and Applications Modular E70 can freely choose the number of cascaded modules according to the user s needs The n...

Page 6: ...uter such as DA card You can use signal generator analog signal source to connect Sensor Monitor LEMO EPG 0B 304 Sensor output signal monitoring terminal Output range is 0 to 10V ZERO Potentiometer Changing mechanical load or temperature changes will cause deviation of sensor zero No operating is required after zero adjustment If closed loop state works normally the zero point potential does not n...

Page 7: ... computer with the controller interface module through RS 422 port access terminal to realize computer control Power supply DC 022B ø2 5 Power connector socket Connect via power adapter or DC power supply Switch KCD1 102 Control the power on and off of the piezo controller ...

Page 8: ...se personal injury or damage modular E70 series piezo controller Installation and using of modular E70 should be close to the power source so that the power plug can be easily and quickly disconnected from the main power source Use included power cord to connect modular E70 series piezo controller system If power cord provided by our company must be replaced please use power cord with large enough...

Page 9: ...analog signal source DA control card output is 0 connect the SMB cable to the SMB interface of modular E70 controller Connect to the computer control mode of PC connect to PC through the cable connection USB interface or RS 232 422 interface socket 5 1 Environmental Conditions The using environment of modular E70 series controller Environmental conditions Condition description Application For room...

Page 10: ... Controller User Manual 5 2 Drawings Type E70 D6S E70 D9S E70 D12S E70 D96S L mm 0 40 80 1280 Note When two modules are cascaded the total width is 90mm and each increase for a module the total width increases by 40mm and so on ...

Page 11: ...er Calculation Average output Sine wave operation mode Pa Upp Us f Cpiezo Pa Average output W Upp Peak and peak drive voltage V Us Drive voltage V Vs Vs Cpiezo Piezo actuator capacitance F f Operating frequency of the sine wave Hz ...

Page 12: ...dule to avoid short circuits The surface of the system chassis and the front panel of the module please do not use an organic solvent for surface wiping 7 2 Transportation and Storage This product is packed in carton Transportation must be carried out under product packaging conditions and direct rain and snow direct contact with corrosive gases and strong vibrations should be avoided during trans...

Page 13: ...andled you can ship it to the following address Address 1F Building I2 No 191 Xuefu Road Nangang District Harbin Heilongjiang 8 2After sales Service Modular E70 does not contain user repairable components Modular E70 must be returned to factory for any service and repair Any part of modular E70 is dismantled there will be no warranty service Modular E70 is a precision instrument which should be ha...

Page 14: ...l 9 Contact us Harbin Core Tomorrow Science Technology Co Ltd Tel 86 451 86268790 Email info coremorrow com Website www coremorrow com Address Building I2 No 191 Xuefu Road Nangang District Harbin HLJ China CoreMorrow Official and CTO WeChat are below ...

Reviews: