8-52 Troubleshooting
Forgotten the login name/password to use the remote management feature through Web
browser:
→
If you have forgotten the login name or password, restore the factory default
including password by changing the BMC configuration jumper switch.
IMPORTANT:
Restoring the factory default clears BMC
configuration that is used for NEC DianaScope to connect with the
server.
If you are using the NEC DianaScope, you need to save the
configuration data into the floppy disk before clearing password.
BMC can be configured and saved with NEC DianaScope Agent and
the system management feature of NEC EXPRESSBUILDER.
1.
Power off the server and unplug the power cord.
2.
Change the jumper switch setting on the I/O riser board as shown below. (See I/O Riser
Board in Chapter 2 for details.)
3.
Connect the power cord.
4.
Wait at least 30 seconds with the power being off, then unplug the power cord.
5.
Restore the BMC configuration jumper switch setting and power on the server for
reconfiguration.
Jumper switch location for
clearing BMC configuration data
Factory-set jumper switch location
Summary of Contents for Express5800/R140a-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Page 278: ...7 18 Maintenance This page is intentionally left blank ...
Page 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Page 430: ...C 4 This page is intentionally left blank ...
Page 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...