8-22 Troubleshooting
Error
code
Error message
Recommended Action
82C0
Mismatch DIMM Type detected in DIMM #1
82C1
Mismatch DIMM Type detected in DIMM #2
82C2
Mismatch DIMM Type detected in DIMM #3
82C3
Mismatch DIMM Type detected in DIMM #4
82C4
Mismatch DIMM Type detected in DIMM #5
82C5
Mismatch DIMM Type detected in DIMM #6
82C6
Mismatch DIMM Type detected in DIMM #7
82C7
Mismatch DIMM Type detected in DIMM #8
82C8
Mismatch DIMM Type detected in DIMM #9
82C9
Mismatch DIMM Type detected in DIMM #10
82CA
Mismatch DIMM Type detected in DIMM #11
82CB
Mismatch DIMM Type detected in DIMM #12
82CC
Mismatch DIMM Type detected in DIMM #13
82CD
Mismatch DIMM Type detected in DIMM #14
82CE
Mismatch DIMM Type detected in DIMM #15
82CF
Mismatch DIMM Type detected in DIMM #16
82D0
Mismatch DIMM Type detected in DIMM #17
82D1
Mismatch DIMM Type detected in DIMM #18
82D2
Mismatch DIMM Type detected in DIMM #19
82D3
Mismatch DIMM Type detected in DIMM #20
82D4
Mismatch DIMM Type detected in DIMM #21
82D5
Mismatch DIMM Type detected in DIMM #22
82D6
Mismatch DIMM Type detected in DIMM #23
82D7
Mismatch DIMM Type detected in DIMM #24
82D8
Mismatch DIMM Type detected in DIMM #25
82D9
Mismatch DIMM Type detected in DIMM #26
82DA
Mismatch DIMM Type detected in DIMM #27
82DB
Mismatch DIMM Type detected in DIMM #28
82DC
Mismatch DIMM Type detected in DIMM #29
82DD
Mismatch DIMM Type detected in DIMM #30
82DE
Mismatch DIMM Type detected in DIMM #31
DIMM numbers shown in error message are
as show below.
DIMM #1 to DIMM #8:
DIMM #1 to DIMM #8 on memory board A
DIMM #9 to DIMM #16:
DIMM #1 to DIMM #8 on memory board B
DIMM #17 to DIMM #24:
DIMM #1 to DIMM #8 on memory board C
DIMM #25 to DIMM #32:
DIMM #1 to DIMM #8 on memory board D
1. Take one of the following measures to
reboot (reset) the server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC
DianaScope Manager.
2. Replace the DIMM that has been replaced
or additionally installed.
3. Replace the failed DIMM.
4. Replace the relevant memory board.
5. If the same error persists, contact your
service representative.
82DF
Mismatch DIMM Type detected in DIMM #32
Summary of Contents for Express5800/R140a-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Page 278: ...7 18 Maintenance This page is intentionally left blank ...
Page 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Page 430: ...C 4 This page is intentionally left blank ...
Page 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...