8-32 Troubleshooting
When STATUS lamp is flashing in green
Description
On-screen
message
Recommended action
CPU Reconfigured
The system has started with processor degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Main] - [Processor Settings] - [Processor Retest]-
[Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
Mem Reconfigured
The system has started with memory degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Advanced] - [Memory Configuration] - [Memory
Retest]- [Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
Mem(xx) D(y) Unc
Err
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in the following location (in memory mirroring configuration).
(xx): Memory board that contains the failed DIMM.
AB: Memory board A or B
CD: Memory board C or D
(y):
Slot number of the memory board that contains the failed DIMM.
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
Mem(x) DIMM(y) C
Err
A correctable error occurred on DIMM in the following location.
(x):
Memory board that contains the failed DIMM.
A: Memory board A
B: Memory board B
C: Memory board C
D: Memory board D
(y):
Slot number of the memory board that contains the failed DIMM.
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
PCI Slot(x) C Err
A correctable error occurred on PCI card installed in PCI slot (x).
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed PCI card.
3. Replace the failed PCI card.
If the same error persists, contact your service representative.
Summary of Contents for Express5800/R140a-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Page 278: ...7 18 Maintenance This page is intentionally left blank ...
Page 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Page 430: ...C 4 This page is intentionally left blank ...
Page 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...