Troubleshooting 8-39
Description
On-screen message
Recommended action
BB +3.3Vs Alm 09
+3.3Vs voltage alarm (upper limit) occurred.
BB +3.3Vs Alm 02
+3.3Vs voltage alarm (lower limit) occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
IO +3.3V AUX Alm 09
+3.3V AUX voltage alarm (upper limit) occurred on I/O riser board.
IO +3.3V AUX Alm 02
+3.3V AUX voltage alarm (lower limit) occurred on I/O riser board.
IO +1.8Vs Alm 09
+1.8Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.8Vs Alm 02
+1.8Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +1.2Vs Alm 09
+1.2Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.2Vs Alm 02
+1.2Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +1.0Vs Alm 09
+1.0Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.0Vs Alm 02
+1.0Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +12V Alm 09
+12V voltage alarm (upper limit) occurred on I/O riser board.
IO +12V Alm 02
+12V voltage alarm (lower limit) occurred on I/O riser board.
IO +5V Alm 09
+5V voltage alarm (upper limit) occurred on I/O riser board.
IO +5V Alm 02
+5V voltage alarm (lower limit) occurred on I/O riser board.
IO +3.3V Alm 09
+3.3V voltage alarm (upper limit) occurred on I/O riser board.
IO +3.3V Alm 02
+3.3V voltage alarm (lower limit) occurred on I/O riser board.
IO +1.5V Alm 09
+1.5V voltage alarm (upper limit) occurred on I/O riser board.
IO +1.5V Alm 02
+1.5V voltage alarm (lower limit) occurred on I/O riser board.
IO +1.0V Alm 09
+1.0V voltage alarm (upper limit) occurred on I/O riser board.
IO +1.0V Alm 02
+1.0V voltage alarm (lower limit) occurred on I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the I/O riser board.
If the same error persists, contact your service representative.
Battery Alm 09
A voltage alarm (upper limit) occurred on Li-Ion battery.
Battery Alm 02
A voltage alarm (lower limit) occurred on Li-Ion battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the Li-Ion battery mounted on base board.
If the same error persists, contact your service representative.
FP Temp Alm 09
A high temperature alarm occurred in front panel.
FP Temp Alm 02
A low temperature alarm occurred in front panel.
BB Temp Alm 09
A high temperature alarm occurred in base board.
BB Temp Alm 02
A low temperature alarm occurred in base board.
Check if fans in the server work normally.
If the same error persists, contact your service representative.
SASBP Temp C Alm
A temperature alarm occurred in SAS riser board.
Summary of Contents for Express5800/R140a-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Page 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Page 278: ...7 18 Maintenance This page is intentionally left blank ...
Page 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Page 430: ...C 4 This page is intentionally left blank ...
Page 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...