9-50 Upgrading Your Server
Installation
Follow these steps to replace the RMC with an optional Advanced Remote Management card
(ARMC).
1.
See section "Preparing for Installation and Removal" described earlier to prepare.
2.
Pull out the server from the rack.
3.
Open the logic cover.
4.
Assemble the management network card that attached to the ARMC and install the card to
the riser card.
5.
Connect the internal cable provided with ARMC to ARMC and the management network
card as shown in the figure below.
The following figure shows the cable rooting of the internal cable.
6.
Reassemble the server.
7.
Turn on the server and check that the no error messages other than the following message
are displayed on the POST screen.
H/W Configuration of BMC is corrupted.
!!Update BMC H/W Configuration by configuration tool!!
!!Refer to BMC configuration manual!!
Refer to Chapter 8 for POST error messages.