9-48 Upgrading Your Server
Removal
Follow these steps to remove or replace the hot-swap fan.
1.
Pull out the server from the rack.
2.
Open the drive cover.
3.
Locate the failed fan.
Fault LED on the fan turns on when a fan failure occurs. A fan failure is also indicated by
NEC ESMPRO and system event log.
4.
While pressing release tabs on the top of the fan, pull the fan up to remove from the fan
slot.
5.
Install the new fan into the vacant slot.
IMPORTANT:
If all the redundant fans are removed. Change the
jumper (J11) setting described earlier in the installation procedure.
If the remote management card is installed in your server, follow these steps to configure
the firmware program.