4-14 Configuring Your Server
Server
Option
Parameter
Description
Your Setting
System
Management
–
System Management submenu is
displayed.
Console
Redirection
–
Console Redirection submenu is
displayed.
Assert NMI on
PERR
Disabled
[Enabled]
Indicates whether PCI PERR is
supported or not.
Assert NMI on
SERR
Disabled
[Enabled]
Indicates whether PCI SERR is
supported or not.
Post Error Pause
Disabled
[Enabled]
Indicates whether POST is aborted once
at the end of POST if an error occurs
during the execution of POST.
AC LINK
Stay Off
[Last State]
Power On
Indicates the AC LINK function. Shows
the state of the power of the server.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC Link] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.
Summary of Contents for Express 5800/120Lh
Page 1: ...N8100 941F 942F 943F NEC Express5800 120Lh User s Guide 1st Edition 08 2004 856 124032 101 00 ...
Page 138: ...5 46 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 174: ...7 12 Maintenance This page is intentionally left blank ...
Page 265: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 274: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 276: ...A 2 Specifications This page is intentionally left blank ...
Page 314: ...F 4 Product Configuration Record Table This page is intentionally left blank ...