Upgrading Your Server 9-45
Installation
Install a DIMM in the following procedure.
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Remove the components as follows:
Side cover
Top air duct
3.
Confirm the socket in which a DIMM is installed.
4.
Open the levers at both ends of the socket.
IMPORTANT:
To avoid damaging the lever, do not apply an excess
force to the lever.
5.
Push the DIMM to the socket straight.
NOTE:
Use extreme care when installing a DIMM. Applying too
much pressure can damage the socket. Keyed DIMMs insert only one
way.
If the DIMM is inserted into the DIMM socket, the lever is automatically closed.
IMPORTANT:
Install a pair of DIMMs at a time. In addition, use a
set of memory devices with the same specification. The specification
of a memory device is described on the label put on the device as
follows:
Example: Frequency of 333 MHz, buffered, capacity of 512 MB,
raw address of 12 bits, column address of 10 bits, and
single side
333 / B / 512 / R12 C10 S
Single side
Column address
Raw address
Capacity
Buffered
Frequency
Summary of Contents for Express 5800/120Lh
Page 1: ...N8100 941F 942F 943F NEC Express5800 120Lh User s Guide 1st Edition 08 2004 856 124032 101 00 ...
Page 138: ...5 46 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 174: ...7 12 Maintenance This page is intentionally left blank ...
Page 265: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 274: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 276: ...A 2 Specifications This page is intentionally left blank ...
Page 314: ...F 4 Product Configuration Record Table This page is intentionally left blank ...