9-46 Upgrading Your Server
6.
Gently push the levers to the upright position until they engage the notches in the DIMM
7.
Install the remove components.
8.
Turn on the power of the server. Then make sure that any error message does not appear
in POST.
If an error message appears, write down the message and review the error message list in
Chapter 8.
9.
Start SETUP to select "Advanced"
→
"Memory Configuration" on menus. Then make
sure that the status of the additional DIMM is set to "Normal" (see Chapter 4).
10.
Set "Reset Configuration Data" on the Advanced menu to "Yes".
This is required to update the hardware configuration. See Chapter 4 for details.
11.
When the Windows operating system is used, set the paging file size to the recommended
value or larger.
Installed memory capacity × 1.5 (See Chapter 5.)