Page 46 of 62
© 2021 Multidyne
FN-64-CHAS Product Manual
>SerBaud 9600
>
The first example command queries the serial baud rate value which is the default of 115200 and the second
command sets it to 9600 baud.
3.10.39
Set Command
Protocol version 3.0
The Set command is used for assigning values to system parameters. See the System Parameter Table for a list
of currently defined parameters. This command supersedes many individual configuration commands.
NOTE:
This command may set Active and/or Stored parameter values. Behavior depends on the parameter and
is defined in the System Parameter Table. Values in Stored memory are loaded at system startup. See System
Parameters for more details.
Command
Description
Set
List all parameter identifiers which can be set, one per line.
Set Parameter Value
Set a parameter’s Active and/or Stored value (depends on parameter).
Examples of listing all writable parameters and setting the “net.ip” parameter.
>Set
ctl.serial.baud
ctl.serial.log
ctl.serial.proto
ctl.serial2.baud
ctl.serial2.log
ctl.serial2.proto
dbg.i2cAckFails
dbg.i2cArbLosses
dbg.i2cBusErrors
dbg.i2cOverruns
dbg.i2cTimeouts
dbg.i2cResets
mtx.sync
net.dhcp
net.gateway
net.ip
net.mac
net.netmask
pnl.cmdEn
pnl.ip
sys.descr
sys.name
sys.type
>
Set net.ip 192.168.2.60
>