Page 45 of 62
© 2021 Multidyne
FN-64-CHAS Product Manual
Command
Description
RemoteSync
Query current value of remote router syncing.
RemoteSync 0 | 1
Enable or disable remote router syncing (1 or 0 respectively).
Examples
>RemoteSync
0
>RemoteSync 1
>FrameIP 192.168.2.61
>
The first command in the above examples queries the current value of the remote sync option, which returns 0
(disabled, the default). The second command enables remote syncing and the final command sets the IP address
of the router to sync (secondary router).
3.10.37
S Command
Routers only
Query the current matrix routing state. Source values for all levels of every destination are shown. This
command without an argument is equivalent to the X Command with no arguments. If an argument value of '1'
is supplied, then the matrix state is displayed with labels. The state of each destination is displayed, one per
line, in the format:
“DestNLvl1”:”SrcLvl1”,”DestNLvl2”:”SrcLvl2”,...
Example
>S1
“Dest1”:”Src4”,”Dest1”:”Src4”
“Dest2”:”Src3”,”Dest2”:”Src3”
“Dest3”:”Src2”,”Dest3”:”Src2”
“Dest4”:”Src1”,”Dest4”:”Src4”
The example above is output from a two level (Video and Audio for example) 4x4 matrix with sources routed in
reverse order, except destination 4, which has a 2nd level break away which is routed from source 4.
3.10.38
SerBaud Command
NOTE:
Superseded by the ctl.serial.baud and ctl.serial2.baud System Parameters.
Query or assign the RS-232 serial port baud rate. The default value is 115200. This value is stored and recalled
on power up.
Command
Description
SerBaud
Query the current serial port baud rate.
SerBaud BAUD
Set the serial port baud rate.
Examples
>SerBaud
115200