Page 29 of 62
© 2021 Multidyne
FN-64-CHAS Product Manual
>
3.10.6
FrameIP Command
NOTE:
Superseded by the
pnl.ip
System Parameter.
Query or assign the remote router IP address. Usually only used on Remote Panel devices or in conjunction
with the RemoteSync Command to create a dual router 3D system. Sets the IP address of the Router system
which the button panel will connect to and control (or which the router will synchronize to when using the
RemoteSync command). This can also be enabled on Router systems with a local button panel to configure the
Router's panel to control a different Router (set to 0.0.0.0 by default to disable remote control and control the
Router device itself). This setting is saved and recalled on power up.
Command
Description
FrameIP
Query IP address of remote Router system to control.
FrameIP IP
Set IP address of remote Router system to control (use 0.0.0.0 on Router systems to disable
remote control).
Example to query and assign the remote Router IP
>FrameIP
192.168.2.60
>FrameIP 192.168.2.61
>
3.10.7
Gateway Command
NOTE:
Superseded by the
net.gateway
System Parameter.
Query or assign the network Gateway IP address. This is usually only needed on Remote Panel systems which
control a Router device on a different network. This setting is saved and recalled on power up.
Command
Description
Gateway
Query IP address of network Gateway.
Gateway IP
Set IP address of network Gateway.
3.10.8
Get Command
Protocol version 3.0
The Get command is used for querying values of currently Active system parameter values. See the System
Parameter Table for a list of currently defined parameters. This command supersedes many individual
configuration commands.
NOTE:
This command queries Active values of parameters which may differ from values in Stored memory.
Values in Stored memory are loaded at system startup and can be queried with the GetS Command. See System
Parameters for more details.
Command
Description
Get
Display all system parameter Active values. Output consists of one parameter per line with
the parameter identifier separated by an equals ‘=’ character and the value.