507 – AL POM Error
ZKP-Number: 14.500.907
Cause
Corrective action
A general POM fault occurred
u
Replace POM.
508 – AL Wrong POM-ID
ZKP-Number: 14.500.908
Cause
Corrective action
POM transmits an unexpected ID
number.
u
Check POM wiring harness.
510 – AL Override applied
ZKP-Number: 27.002.010
Cause
Corrective action
Override was activated
u
Deactivate Override pushbutton again.
515 – AL Starter Not Engaged
ZKP-Number: 21.090.926
Cause
Corrective action
Starter on CPM / POM could not
be engaged. Start is canceled
when the number of automatic
start attempts from PR
2.1090.134 Number of Start
Attempts has been used up.
Check CPM, starter and cabling.
1. Repeat starting attempt
2. Check CPM, starter and cabling
519 – Oillevel Calibration Error
ZKP-Number: 10.158.921
Cause
Corrective action
Error writing calibration value into
flash or SD of level sensor
1. Check sensor and cabling, replace as necessary.
2. Contact Service.
521 – SS P-Lube Oil Mid Val
ZKP-Number: 20.480.289
Limit value 1
Cause
Corrective action
Average oil pressure value from
three sources is too low
u
Check oil level, top up as necessary.