7.2 Engine Control Unit ADEC (ECU 7) for Series 4000 genset
engines – Fault messages
Possible engine responses to yellow alarm:
Warning, power limitation/reduction, speed limitation, engine stop
Possible engine responses to red alarm:
Engine stop, power limitation/reduction, speed limitation, warning
Procedure following an automatic safety shutdown (→ Page 124)
003 – HI T-Fuel
ZKP-Number: 2.0122.931
Limit value 1
Cause
Corrective action
Fuel temperature too high
u
Contact Service.
004 – SS T-Fuel
ZKP-Number: 2.0122.932
Limit value 2
Cause
Corrective action
Fuel temperature too high. Engine
stop
u
Contact Service.
005 – HI T-Charge Air
ZKP-Number: 2.0121.931
Limit value 1
Cause
Corrective action
Charge-air temperature too high
1. Reduce power.
2. Check intercooler.
006 – SS T-Charge Air
ZKP-Number: 2.0121.932
Limit value 2
Cause
Corrective action
Charge-air temperature too high.
Engine stop
1. Reduce power.
2. Check intercooler.
138 | Troubleshooting | MS150093/05E 2018-12
TIM-ID: 0000008506 - 006