301 – AL Timing Cylinder A1
ZKP-Number: 1.8004.500
Cause
Corrective action
Time-of-flight measuring fault of
injector: Time-of-flight measured
value extremely low or extremely
high.
u
Replace injector concerned if the fault message appears frequently
(→ Page 210).
302 – AL Timing Cylinder A2
ZKP-Number: 1.8004.501
Cause
Corrective action
Time-of-flight measuring fault of
injector: Time-of-flight measured
value extremely low or extremely
high.
u
Replace injector concerned if the fault message appears frequently
(→ Page 210).
303 – AL Timing Cylinder A3
ZKP-Number: 1.8004.502
Cause
Corrective action
Time-of-flight measuring fault of
injector: Time-of-flight measured
value extremely low or extremely
high.
u
Replace injector concerned if the fault message appears frequently
(→ Page 210).
304 – AL Timing Cylinder A4
ZKP-Number: 1.8004.503
Cause
Corrective action
Time-of-flight measuring fault of
injector: Time-of-flight measured
value extremely low or extremely
high.
u
Replace injector concerned if the fault message appears frequently
(→ Page 210).
305 – AL Timing Cylinder A5
ZKP-Number: 1.8004.504
Cause
Corrective action
Time-of-flight measuring fault of
injector: Time-of-flight measured
value extremely low or extremely
high.
u
Replace injector concerned if the fault message appears frequently
(→ Page 210).
MS150093/05E 2018-12
| Troubleshooting | 157
TIM-ID: 0000008506 - 006