Performance data
ID
1
2
3
Rated engine speed
A
rpm
1500
1500
1500
Fuel stop power ISO 3046
A
kW
2420
2670
2849
General conditions (for maximum power)
ID
1
2
3
Intake depression (new filter)
A
mbar
15
15
15
Intake depression, max.
L
mbar
50
50
50
Model-related data (basic design)
ID
1
2
3
Number of cylinders
-
20
20
20
Cylinder arrangement: V-angle
Degrees
(°)
90
90
90
Bore
mm
170
170
170
Stroke
mm
210
210
210
Displacement, cylinder
Liters
4.77
4.77
4.77
Displacement, total
Liters
95.4
95.4
95.4
Compression ratio
-
16.4
16.4
16.4
Number of inlet valves per cylinder
-
2
2
2
Number of exhaust valves, per cylinder
-
2
2
2
Air / exhaust gas
ID
1
2
3
Charge-air pressure before cylinder - DL
R
bar abs
2.5
2.7
2.9
Charge-air pressure before cylinder - BL
R
bar abs
2.7
2.9
3.2
Coolant system (HT circuit)
ID
1
2
3
Coolant temperature (at engine connection: outlet to
cooling equipment)
A
°C
100
100
100
Coolant temperature after engine, limit 1
L
°C
102
102
102
Coolant temperature after engine, limit 2
L
°C
104
104
104
Coolant antifreeze content, max.
L
%
50
50
50
Pressure loss in off-engine cooling system, max.
L
bar
0.7
0.7
0.7
Coolant system (LT circuit)
ID
1
2
3
Coolant temperature before charge-air cooler (at en-
gine inlet: from cooling equipment)
A
°C
45
45
45
Coolant antifreeze content, max.
L
%
50
50
50
Pressure loss in off-engine cooling system, max.
L
bar
0.7
0.7
0.7
MS150093/05E 2018-12
| Technical Data | 115