086 – HIHI T-Umblasen
ZKP-Number: 2.0128.932
Limit value 2
Cause
Corrective action
Recirculation temperature too
high
u
Reduce power.
089 – SS Engine Speed too Low
ZKP-Number: 2.2500.030
Cause
Corrective action
Engine speed too low
u
Observe any other messages.
090 – SS Idle Speed Not Reached
ZKP-Number: 2.1090.925
Cause
Corrective action
Idling speed not attained
u
Contact Service.
091 – SS Release Speed Not Reached
ZKP-Number: 2.1090.924
Cause
Corrective action
Runup speed was not attained
u
Contact Service.
092 – SS Starter Speed Not Reached
ZKP-Number: 2.1090.923
Cause
Corrective action
Starter speed was not attained.
Termination of starting sequence.
Starter rotates too slowly or does
not rotate at all.
u
Contact Service.
093 – SS T-Preheat
ZKP-Number: 2.1090.922
Limit value 2
Cause
Corrective action
Preheating temperature too low.
Coolant temperature too low for
engine start. Engine start
interlock active.
u
Check preheater.