184 – AL CAN PU-Data Flash Error
ZKP-Number: 2.0500.684
Cause
Corrective action
A programming error occurred
when attempting to copy a
received PU data module into the
Flash module
u
Contact Service.
186 – AL CAN1 Bus Off
ZKP-Number: 2.0500.686
Cause
Corrective action
CAN controller 1 is in “Bus-Off”
status
1. Check CAN bus for short circuit, rectify short circuit as necessary.
2. Check shielding, improve shielding as necessary.
3. Contact Service.
187 – AL CAN1 Error Passive
ZKP-Number: 2.0500.687
Cause
Corrective action
CAN controller 1 has indicated a
warning
1. Check CAN bus for short circuit, rectify short circuit as necessary.
2. Check shielding, improve shielding as necessary.
3. Contact Service.
188 – AL CAN2 Bus Off
ZKP-Number: 2.0500.688
Cause
Corrective action
CAN controller 2 is in “Bus-Off”
status. => automatic changeover
to CAN 1. Short circuit, massive
interference or baud rate
incompatibility.
1. Check CAN bus for short circuit, rectify short circuit as necessary.
2. Check shielding, improve shielding as necessary.
3. Contact Service.
189 – AL CAN2 Error Passive
ZKP-Number: 2.0500.689
Cause
Corrective action
CAN controller 2 has indicated a
warning
1. Check CAN bus for short circuit, rectify short circuit as necessary.
2. Check shielding, improve shielding as necessary.
3. Contact Service.
190 – AL EMU Parameter Not Supported
ZKP-Number: 2.0500.690
Cause
Corrective action
EMU parameters are not
supported
u
Contact Service.
150 | Troubleshooting | MS150093/05E 2018-12
TIM-ID: 0000008506 - 006