244 – SD P-Lube Oil (R)
ZKP-Number: 1.8004.621
Cause
Corrective action
Redundant lube oil pressure
sensor faulty. Short circuit or wire
break.
u
Check sensor and cabling, replace as necessary.
Error cleared after restarting the engine.
245 – SD ECU Power Supply Voltage
ZKP-Number: 2.8006.589
Cause
Corrective action
Internal ECU fault. Electronics
faulty.
u
Replace Engine Control Unit.
266 – SD Speed Demand
ZKP-Number: 2.8006.586
Cause
Corrective action
Analog speed setting faulty. Short
circuit or wire break.
1. Check cabling.
2. Check speed setpoint.
268 – SD Spinning Value
ZKP-Number: 28.006.591
Cause
Corrective action
Analog skid signal faulty. Short
circuit or wire break.
u
Check sensor and cabling, replace as necessary.
269 – SD Loadp.Analog filt
ZKP-Number: 2.8006.588
Cause
Corrective action
Filtered analog signal of load
pulse missing. Short circuit or
wire break.
u
Check wiring, replace as necessary.
Error cleared after restarting the engine.
270 – SD Frequency Input
ZKP-Number: 2.8006.590
Cause
Corrective action
Frequency input faulty. Short
circuit or wire break.
1. Check cabling.
2. Check speed demand transmitter.
3. Contact Service.
156 | Troubleshooting | MS150093/05E 2018-12
TIM-ID: 0000008506 - 006