362 – AL Power Stage High
ZKP-Number: 1.8004.497
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty: start
ITS). Check additional messages if
ITS indicates diagnosis
“Electronics OK” (e.g. cabling
faulty).
1. Check solenoid valve cabling.
2. Replace Engine Control Unit.
363 – AL Stop Power Stage
ZKP-Number: 1.8004.560
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty: start
ITS).
1. Check cabling.
2. Attempt to restart engine.
365 – AL Stop MV-Wiring Ground
ZKP-Number: 1.8004.561
Cause
Corrective action
Injector cabling fault: If bit
“1.1020.021” (Power Stage
Failure: Stop engine) is set, engine
is additionally stopped in this
case.
• Short circuit of injector positive
connection to ground of one or
more injectors
• Short circuit of the negative
injector connection or of one or
more injectors to ground
1. Check cabling.
2. Attempt to restart engine.
371 – AL Wiring TO 1
ZKP-Number: 1.8004.634
Cause
Corrective action
Short circuit or wire break at
transistor output 1 (TO 1)
1. Check charger valve/cabling, repair as necessary.
2. Replace Engine Control Unit.
372 – AL Wiring TO 2
ZKP-Number: 1.8004.635
Cause
Corrective action
Short circuit or wire break at
transistor output 2 (TO 2)
1. Check recirculation valve/cabling, repair as necessary.
2. Replace Engine Control Unit.