Continuation “Main Menu”:
No.
Parameter
Range
Default
003
F1-F2 Selection
(Basic Frequency Selection)
:
Important notes for DS240 / DS246 see chapter
This Parameter determines, which of both input frequencies of sensor1
or sensor2 (see parameter 000) is monitored and processed as basic
frequency.
The basic frequency selection affects the following outputs:
-
Analog Output
-
Control Outputs
-
Relay Outputs
And thus the following menus:
- preselected thresholds in the Preselect Menu (see chapter
- switching behaviors in the Switching Menu (see chapter
- analog output in the Analog Menu (see chapter
0
Frequency of sensor1 serves as basic frequency
1
Frequency of sensor2 serves as basic frequency
0 - 1
0