Ds230_03a_oi_e.doc / Jun-15
Page 67 / 100
Continuation “Switching Menu”:
No.
Parameter
Range
Default
054
Start-up Mode
(start-up delay time window)
:
Delay time window until the monitoring function is activated. Only
useful in combination with switching mode 1 and 5 (see chapter
).
To use the start-up delay, it must be assigned to an output (see
parameter 055).
The start-up delay will be activated:
a) with next power-up
b) always when after standstill a frequency is detected again
0
no start-up delay
1
start-up delay 1 second
2
start-up delay 2 seconds
3
start-up delay 4 seconds
4
start-up delay 8 seconds
5
start-up delay 16 seconds
6
start-up delay 32 seconds
7
start-up delay 64 seconds
8
start-up delay 128 seconds
9
automatically, until the value has been exceeded
for the first time (see chapter
0 - 9
0
The defined delay time window is valid for all outputs
(see parameter 055).
055
Startup Output
(assignment of a start-up delay to outputs)
:
By using a 5 bit binary code the start-up delay function can be assigned
to the outputs. Settings see below:
Output:
RELAY
OUT4
OUT3
OUT2
OUT1
Bit
5
4
3
2
1
Binary:
10000
01000
00100
00010
00001
Value:
16
8
4
2
1
Example:
A setting of „17“ (binary 10001) means that a start-up delay is assigned
to OUT1 and to the relay-output.
0 - 31
0
During the start-up delay no frequency monitoring resp. frequency comparison
is processed!
The setting of a start up delay time is only possible when the parameter "Switch Mode
OUT1" is 1, 2, 5 or 6. (see parameter 039 and following., marking {A})
Summary of Contents for DS230 Series
Page 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Page 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Page 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Page 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...