6.13.
„Operational Mode“ = 7
Mode
7
Sensor1
[X8 | RS422 IN 1]
Incremental RS422 / TTL encoder
(A, /A, B, /B)
Sensor2
[X9 | RS422 IN 2]
Incremental RS422 / TTL encoder
(A, /A, B, /B)
Control1
[X10 | CONTROL IN]
HTL/PNP control signal
(complementary)
Control2
Control signal input not available
Achievable
Safety Level
Speed
SIL3 / PLe
Direction
SIL3 / PLe
Standstill
SIL3 / PLe
This mode (only DS23x) allows to evaluate a dual channel system, equipped with two identical
RS422/TTL incremental encoders. The encoder must be performed in accordance to chapter
A DS230 variant reproduces selectively the input frequency of Sensor1 or
Sensor2 to the splitter output [X4 | RS422 OUT].
The inputs at [X6 | SINCOS IN 1] and [X7 | SINCOS IN 2] have no function.
Both control inputs (Control1 and Control2) are available for control signals at
[X10 | CONTROL IN].