Sensor Channel Adaption
When using two sensors with a different number of pulses or in case of a mechanical speed
reduction between both encoders, then the higher frequency must be adjusted to the lower one. For
this calculation the scaling factors (see chapter
are used.
In the example above the frequency 2 is smaller by the factor 0.0994 than frequency 1.
For adjustment, the “Multiplier 1” (parameter 014) should be set to 994 and the “Divisor 1”
(parameter 015) to 10.000.