Ds230_03a_oi_e.doc / Jun-15
Page 62 / 100
„Preselect Menu“
No.
Parameter
Range
Default
027
Preselect OUT1.H:
Upper switching point of output OUT1 [X2:1-2]
-500 000.0
-
500 000.0
(Hz)
(see basic
frequency,
Parameter 003)
10 000
028
Preselect OUT1.L:
Lower switching point of output OUT1 [X2:1-2]
20 000
029
Preselect OUT2.H:
Upper switching point of output OUT2 [X2:3-4]
30 000
030
Preselect OUT2.L:
Lower switching point of output OUT2 [X2:3-4]
40 000
031
Preselect OUT3.H:
Upper switching point of output OUT3 [X2:5-6]
50 000
032
Preselect OUT3.L:
Lower switching point of output OUT3 [X2:5-6]
60 000
033
Preselect OUT4.H:
Upper switching point of output OUT4 [X2:7-8]
70 000
034
Preselect OUT4.L:
Lower switching point of output OUT4 [X2:7-8]
80 000
035
Preselect REL1.H:
Upper switch-point of the relay output [X1:1-2]
1 000
036
Preselect REL1.L:
Lower switching point of the relay output [X1:1-2]
2 000
037
Reserved
038
Reserved
The upper switching point (index .H) is only active, if no error can be detected and if an
external signal is triggered to the control input according to chapter
The operator has to assign the values to the switch-points correctly.
The “High” value must always be higher than the “Low” value.
Summary of Contents for DS230 Series
Page 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Page 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Page 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Page 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...