Ds230_03a_oi_e.doc / Jun-15
Page 60 / 100
7.4.4.
Sensor2 Menu
No.
Parameter
Range
Default
019
Direction2:
The description of the
sensor2 Parameters is
identically with the sensor1
menu, but all settings are
related to sensor2 which is
specified by the „Operation
Mode“.
0 - 1
0
020
Multiplier2:
1- 10 000
1
021
Divisor2:
1 - 10 000
1
022
Position Drift2:
0 - 100 000
0
023
Phase Err Count2:
1 - 1 000
10
024
Set Frequency2:
-500 000.0
-
500 000.0 (Hz)
0
025-026 Reserved
When using 2 encoders with differing pulse rates or in case of a mechanical reduction
between both encoders, the higher frequency must be converted to the lower frequency
by using the scaling factors (see chapter
).
Summary of Contents for DS230 Series