Ds230_03a_oi_e.doc / Jun-15
Page 53 / 100
Continuation “Main Menu”:
No.
Parameter
Range
Default
001
Sampling Time:
The configured value corresponds to the minimum measurement time.
The Parameter is used as a filter in case of irregular frequencies. This
Parameter has a direct influence to the reaction time of the unit. The
setting is valid for both inputs channels.
0,001 - 9,999
(sec.)
0,001
002
Wait Time:
Defines the period time of the lowest frequency resp. the waiting time
between 2 rising edges, which is detected as „Frequency = 0“ by the
unit.
All frequencies with a period longer than the Wait Time value will be
interpreted as frequency = 0.
0,010 Frequency = „0“ with frequencies smaller than 100 Hz
…
9,999 Frequency = „0“ with frequencies smaller than 0.1 Hz
The setting is valid for both inputs channels.
0,010 - 9,999
(sec.)
1,000
Summary of Contents for DS230 Series
Page 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Page 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Page 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Page 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...