Ds230_03a_oi_e.doc / Jun-15
Page 74 / 100
7.4.8.
Serial Menu
No.
Parameter
Range
Default
068 Serial Unit No.
(assigns a serial unit number)
:
The devices can be assigned by unit numbers between 11 and 99
(default setting = 11).
Unit numbers which contain a “0“ are forbidden because these are used
for group- or bulk-addressing.
11 - 99
11
069 Serial Baud Rate
(serial transmission speed)
:
0:
9 600 Baud
1:
4 800 Baud
2:
2 400 Baud
3:
1 200 Baud
4:
600 Baud
5:
19 200 Baud
6:
38 400 Baud
7:
56 000 Baud
8:
57 200 Baud
9:
76 800 Baud
10:
115 200 Baud
0 - 10
0
070 Serial Format
(format of the serial data)
:
0 - 9
0
0:
7 data bits,
parity even, 1 stop bit
1:
7 data bits,
parity even, 2 stop bits
2:
7 data bits,
parity odd,
1 stop bit
3:
7 data bits,
parity odd,
2 stop bits
4:
7 data bits,
no parity*,
1 stop bit
5:
7 data bits,
no parity*,
2 stop bits
6:
8 data bits,
parity even, 1 stop bit
7:
8 data bits,
parity odd,
1 stop bit
8:
8 data bits,
no parity*,
1 stop bit
9:
8 data bits,
no parity*,
2 stop bits
*) „no parity“: no secure data transmission guaranteed.
„Parity even“ or „Parity odd“ must be set for a secure data transmission.
Summary of Contents for DS230 Series
Page 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Page 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Page 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Page 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...