When you release the E-stop switch, the control system should receive power and begin to boot-
up. After a short period of time you will see the touchscreen become active and display the boot-
up sequence.
If the touchscreen remains blank, check that there is mains power to the machine and to the
E-stop switch, then use the RAP that follows.
Is there power to the ATX PSU?
Check that there is V AC across the ATX PSU power cord.
Identify reason for no power to ATX PSU.
Check the top fuse, (See Page 66).
If this fuse has blown it must be replaced with a
T500mA fuse, Morgana part number 681-020. (230V 50Hz Machines only)
T1A fuse, Morgana part number 681-021. (110V 60Hz Machines only).
Is there a V DC output from the ATX PSU? (See page 61).
Replace the ATX PSU.
Does the cooling fan run on the mini-ITX motherboard? (See page 61).
Replace the mini-ITX motherboard.
Is there a V DC power to the Touchscreen?
Repair the wiring connection.
Replace the Touchscreen Assembly.
FAULT:- No Touchscreen Display, (Machine will not boot up).
IMPORTANT.
·
·
Yes
No
Yes
No
Yes
No
Yes
No
For Error messages see Operators Manual