Page 58
Calibration
This is the final calibration procedure and closely follows the 'Calibration' flow chart. You
must have completed all previous setup procedures leading up to this final calibration.
If additional information is required for setting up the various crease and fold variations,
please refer to the operators manual.
The delivery roller needs to be calibrated to ensure the correct positions are achieved
during automatic setup. In the 'Tools' menu adjust the 'Delivery Roller Trim' until the upper
stopping position is within 3mm of the perforator cover.
Ensure K1 & K2 are set to zero before setting/Adjusting lead edge and stretch.
Using the test stock, setup folds to 50 and 370, Check the fold positions and using the
'Stretch' and 'Lead Edge' settings in the 'Tools' menu, adjust the fold positions until they are
correct.
- Always Set the Stretch first i.e. 320mm between folds.
Using the test stock, setup 'fold only' at 100 and 250. Check the fold positions and adjust if
necessary using the 'Fold 1'
and 'Fold 2'
adjustments in the 'Tools’ Menu.
Do not use damaged Test Stock.
12.
13.
Delivery Roller
Fold Positions
NOTE
WARNING.
FOLDING