Page 39
3.2.
3.3.
3.4.
3.5.
3.6.
Adjust the Layside Housing, using the shaft flats on the operator side, until a light
pressure is felt on the operator strip & then temporarily tighten one of the housing
set screws on the op side. (the top one).
Now adjust the operator side housing, using the M5 cap head screw, to give a very
light 'pull' on the test strips & tighten the operator side securing screw
(an M5 cap head screw in the radial slot in the edge of the Operator Side Plate)
Check the 'feel' on a complete rotation of the roller to ensure the roller is concentric
& repeat from 3.2 until both strips have the same (very light) feel on the test strips.
Finally, tighten both of the opside housing screws (M5 set screws).
Now, using the operator side securing screw, (the M5 cap head screw in the radial
Slot) adjust the whole roller assembly to give a heavy pull on the test strips.
(See FIG.3.1.A).
Re-tighten the operator side securing screw and re-check. Repeat until parallel.
FIG.3.1.B
80gsm Test Strips
Shaft Flats
SYSTEM
Autofold Pro