Page 43
5.4. Rotate the Delrin cam
5.5.
5.6.
downwards until the jig assembly fits correctly, adjust the
eccentric shaft if required, tighten the two cap head screws on the ends
of the eccentric shaft.
Remove the Right Hand Shoulder Bolt from the Setting Jig, rotate the Jig (and the Knife
Drive Hub to which it is fixed) and the drive motor pulley, fully Clockwise and insert the
Shoulder Bolt through the previously unused hole in the Jig
and into the Left Hand Knife Drive Hub. This locks the knives in the other of the two
correct stop positions.
Re-Check the positions of the Setting Jig. Repeat above procedure if the shoulder
screws do not slide into the jig smoothly
(which should now be on the
right)
SYSTEM