Page 18
FOLDING
SECTION E
ELECTRICS: REMOVAL/REFITTING PCB’s
REPLACEMENT OF MAIN CONTROL P.C.B.
This PCB controls all functions of the machine and houses the Main Program PCB.
The use of an antistatic wrist band should be used during work on the main control PCB.
Unplug all the green plugs from the PCB.
Using a posi-drive screw driver, unscrew the five fixing screws and carefully remove the PCB.
Switch the mains power off and disconnect from the mains supply.
Access is from the Lay Side Door. (see section on covers for removal).
When fitting a new board it is important that the switch,
, must be set in the correct
position. For machines with Serial No. 180209 or higher the switch must be set over to the left
in the
position; these machines were fitted with
as
standard. For machines with Serial numbers earlier than 180209 the switch must generally be
set over to the right in the
position, unless the machine has been upgraded to
include
Earlier Machines that have been upgraded with
will have a main processor revision of F1.2x2 or higher and a
touchscreen software revision of AF1.0x1 or higher; for these machines the switch must be set
over to the left in the
position. See technical bulletin TB2744 Iss.B. for further
information.
SWITCH (SW1)
NOTE.
SW1
AUTO EDGE
Lead Edge Auto Sensing
POT EDGE
Lead Edge Auto Sensing.
Lead
Edge Auto Sensing
AUTO EDGE