FOLDING
2. CHECK THE ITX MOTHER BOARD AS FOLLOWS:-.
(i) Remove the 3V lithium disc battery from the ITX mother board and check the voltage using
a multi meter. If the voltage is less than 1.5V replace the ITX mother board. If the voltage is
more than 1.5V refit the battery to the board.
1. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
2. DISPOSE OF BATTERIES ACCORDING TO THE MANUFACTURERS INSTRUCTIONS.
(ii) With the power to the machine turned on, link pins 3 & 4 of the connector shown in FIG.2
with a small flat bladed screwdriver. The fan on the board will start spinning, wait for 30
seconds and the machine will restart and boot up as normal.
When the power to the machine is turned off and back on again the procedure of linking
pins 3 & 4 must be repeated to restart the machine. This is therefore only a short term fix to
get the customer up and running, if a replacement ITX mother board is not readily available.
The ITX mother board has a lithium battery fitted, the board together with its battery must be
recycled
DISPOSE OF BATTERIES ACCORDING TO THE MANUFACTURERS INSTRUCTIONS.
CAUTION.
NOTE.
IMPORTANT RECYCLING NOTE:-
CAUTION.
in compliance with agreed national Procedures Please contact your local disposal
authority for information
.
.
PINS 3 & 4