NICE7000 User Manual 6 Function Code Table
- 113 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
F6-11
Elevator function
selection 3
Bit0: Fire emergency display
Bit1: Firefighter operation display
Bit2: Direction display at micro-
leveling
Bit3: Determined direction display
in attendant state
Bit4: No direction display at
automatic stop
Bit5: Elevator lock at door open
Bit6: Display available at elevator
lock
Bit7: Elevator lock at any floor hall
call
Bit8: Clear floor number in
advance
Bit9: Clear floor number in
advance in attendant state
Bit10: Displaying next arriving
floor number
Bit11: Blinking at arrival
Bit12: Door re-open during door
open delay
Bit13: Door re-open after car call
of the present floor
Bit14: Door re-open at door close
limit
Bit15: Reserved
0
-
★
F6-12
Blinking advance
time
0.0–15.0
2.0
s
☆
F6-13
Parking floor 2 start
time
00.00–23.59
0
-
★
F6-14
Parking floor 2 end
time
00.00–23.59
0
-
★
F6-15
Parking floor 2
0 to F6-00
0
-
★
F6-16
Fire emergency
floor 2
0 to F6-00
0
-
★
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......