NICE7000 User Manual 7 Description of Function Codes
- 151 -
36: Service floor switchover
If this signal is active, the time-based service 1 remains valid.
37: Fire emergency floor switchover
The NICE7000 supports two fire emergency floors. Fire emergency floor 1 is the default
one. If this signal is active, the elevator stops at fire emergency floor 2.
38: Parking floor switchover
The NICE7000 supports two parking floors. Parking floor 1 is the default one. If this signal is
active, the elevator stops at parking floor 2.
Different parking floors can be set for different time periods. For details, see group F6
parameters.
39: Down collective selective switch
The system starts the down collective selective function when the start time set in group Fd
is reached or this signal is active.
40: Peak service
Within the peak service time set in group Fd, the system starts the peak service when the
number of car calls at the peak service floor exceeds 3 or this signal is active.
41: Fire emergency start signal
In this firefighter operation state, the elevator starts running when this signal is active.
It is used when there are special requirements for fire emergency running.
42: Back door selection signal 43: Back door forbidden signal
When opposite door control is used, these two signals are used to allow or forbid door 2.
44: Light-load signal 45: Half-load signal
It is used for allocation of elevators in parallel or group mode and nuisance judgment in the
anti-nuisance function.
46: Double door control signal
In opposite door control, if the back door is not forbidden, both doors open if this signal is
active.
47: Motor input
The group control system allocate calls to elevators in energy-saving principle when standby
power supply is used.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F5-29
X29 function selection
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal
4
-
★
F5-30
X30 function selection
5
-
★
F5-31
X31 function selection
5
-
★
These parameters are used to set the functions of heavy-current detection input terminals
X29 to X31.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......