7 Description of Function Codes NICE7000 User Manual
- 144 -
Bit
Function
Description
Remarks
Bit6 Stop position
1
Stop at the base floor
-
0
Stop at nearest landing floor
-
Bit7
Startup
compensation
1
Startup torque compensation valid in
emergency evacuation running
-
0
Invalid
-
Bit8 to Bit15: reserved
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-15
Normal speed emergency
evacuation speed
0.080–0.500
0.080
m/s
★
F3-16
Acceleration rate at
emergency evacuation
0.500–2.000
0.500
m/s
2
★
It is used to set the acceleration rate at emergency evacuation.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-17
Normal speed emergency
evacuation times
0–10
0
-
★
It is used to set the maximum normal speed emergency evacuation times allowed.
This parameter is valid only when normal speed emergency evacuation is allowed (F3-14
Bit2 = 1).
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-18
Zero-speed control time at startup
0.000–1.000
0.200
s
★
F3-19
Brake release delay
0.000–1.5.000
0.600
s
★
F3-20
Zero-speed control time at end
0.000–1.000
0.300
s
★
F3-21
Brake apply delay
0.200–1.500
0.200s
s
★
These parameters are used to set the time related to the zero-speed holding current output
and braking action delay.
F3-18 (Zero-speed control time at startup) specifies the time from output of the RUN
contactor to output of the brake contactor, during which the controller performs excitation on
the motor and outputs zero-speed current with large startup torque.
F3-19 (Brake release delay) specifies the time from the moment when the system sends
the brake release command to the moment when the brake is completely released, during
which the system retains the zero-speed torque current output.
F3-20 (Zero-speed control time at end) specifies the zero-speed output time when the
running curve ends.
F3-21 (Brake apply delay) specifies the time from the moment when the system sends the
brake apply command to the moment when the brake is completely applied, during which
the system retains the zero-speed torque current output.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......