NICE7000 User Manual 9 EMC
- 231 -
Interference Type
Solution
Communication
interference
•
Connect the motor housing to the PE of the controller.
•
Connect the PE of the controller to the PE of the mains voltage.
•
Add a safety capacitor to the power input cable and wind the cable
with magnetic rings.
•
Add a matching resistor between the communication cable source
and the load side.
•
Add a common grounding cable besides the communication cable.
•
Use a shielded cable as the communication cable and connect the
cable shield to the common grounding point.
I/O interference
•
Enlarge the capacitance at the low-speed DI. A maximum of 0.11 uF
capacitance is suggested.
•
Enlarge the capacitance at the AI. A maximum of 0.22 uF is
suggested.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......