7 Description of Function Codes NICE7000 User Manual
- 184 -
Function Code Parameter Name
Setting Range
Default
Unit
Property
FC-47
11th fault subcode
0–65535
0
-
●
FC-48
11th fault month and day
0–1231
0
MM.DD
●
FC-49
11th fault hour and minute
0–2359
0
HH.MM
●
FC-50
11th fault information
0–65535
0
-
●
These parameters record the first 10 faults of the elevator among the last 20 faults.
The fault code is a 4-digit number. The two high digits indicate the floor where the car is
located when the fault occurs, and the two low digits indicate the fault code. For example,
the FC-46 is 0835, indicating that when the 11th fault (Err35) occurs, the car is near floor 8.
The fault subcode is used to locate the causes of the fault. The specific fault time is
recorded in month, day, hour and minute.
Group Fd: Parallel/Group Control Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fd-00
Number of elevators in
parallel/group mode
1–3
1
-
★
Fd-01
Elevator No.
1–3
1
-
★
These parameters are used to set the number of elevators and elevator No. in in parallel//
group mode.
The NICE7000 supports parallel control of two elevators or group control of up to eight
elevators.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......