Introduction NICE7000 User Manual
- 10 -
Full-load indication
When the elevator is full-loaded, a full-load indication is displayed on the
HCBs and the elevator directly runs to the desired floors.
Interface for
intelligent residential
management
The system provides an interface for intelligent residential management
to perform remote monitoring on the state of elevators in the residential
district.
Energy-saving Functions
Car energy-saving
If there is no running command within the set time, the system
automatically cuts off the power supply to the lamp and fan in the car.
Energy-saving
running with standby
power supply
When the normal power supply is interrupted and the EPS is used, the
system reduces the running speed of the elevator in the prerequisite of
guaranteeing the smooth running curve.
Arrival gong disabled
at night
Within the set time period, the arrival gong is disabled.
Energy-saving of idle
door machine
After the car lamp is turned off, the system does not output the door close
command, which reduces power consumption of the door machine.
4. Optional functions
Function
Description
Remark
Micro-leveling
After landing at a floor, the elevator may move upward or
downward due to the load change and the car door is not
aligned with the ground, which is inconvenient for in and out
of passengers and goods. In this case, the system allows the
elevator to run to the leveling position in the door open state
at the leveling speed.
MCTC-SCB
required
Power failure
emergency
evacuation
For the elevator configured with EPS, the system uses the
EPS to implement low-speed self-rescue in the case of
power failure.
EPS required
Onsite
commissioning
The system can control and monitor running of elevators by
using the NEMS software.
NEMS software
required
Residential
monitoring
The control system can be connected to the terminal in the
monitoring room. By using the NEMS software, you can view
the floor position, running direction, and fault state of the
elevator.
NEMS,
accessories,
and MCTC-MIB
required
Door pre-open
During normal stop, when the elevator speed is smaller than
0.2 m/s and the door zone signal is active, the system shorts
the door lock by means of the shorting door lock circuit
contactor and outputs the door open signal, implementing
door pre-open. This improves the elevator use efficiency.
MCTC-SCB
required
IC card
Passengers need to use the IC card to go to floors that
require authorization.
IC card required
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...