NICE7000 User Manual 7 Description of Function Codes
- 183 -
It is used to set the door open holding time when there is a car call. The elevator closes the
door immediately after receiving a door close command.
Function Code
Parameter Name
Setting Range
Default Unit
Property
Fb-17
Door open holding time at base floor
1–30
10
s
☆
It is used to set the door open holding time after the elevator arrives at the base floor. The
elevator closes the door immediately after receiving a door close command.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-18
Door open delay
10–30000
30
s
☆
It is used to set the door open holding time when there is door open delay input. The
elevator closes the door immediately after receiving a door close command.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-19
Special door open holding time
10–1000
30
s
☆
It is used to set the door open holding time when there is a disability call.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-20
Manual door open holding time
1–60
10
s
☆
It is used to set the door open limit delay in the case of manual door. This parameter is valid
when the manual door function is used.
Group FC: Brief Fault Information
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FC-00
Designated fault
0–99
0
-
☆
It is used to designate the fault to be monitored.
The designated fault code is saved in parameters of group E9, and will not be overwritten.
Function Code Parameter Name
Setting Range
Default
Unit
Property
FC-01
20th fault code
0–6299
0
-
●
FC-02
20th fault subcode
0–65535
0
-
●
FC-03
20th fault month and day
0–1231
0
MM.DD
●
FC-04
20th fault hour and minute
0–2359
0
HH.MM
●
FC-05
20th fault information
0–65535
0
-
●
···
FC-46
11th fault code
0–6299
0
-
●
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......