NICE7000 User Manual 5 System Commissioning and Functions
- 93 -
Function
Code
Parameter
Name
Setting Range
Setting in Parallel
Control
Setting in Group
Control
Fd-01
Elevator No.
1–8
1: master elevator
2: slave elevator
1: master elevator
2–8: slave elevator
Fd-02
Parallel/Group
control mode
0: Parallel control
Applicable to parallel
control of 2 elevators
2: Group control of
traditional mode
Applicable to group
control
The parallel/group control function has the following features:
•
When hall calls are registered, the system calculates the response time of the elevators
in parallel/group control in real time (based on distance, elevator arrival, door open/
close), and responds to all calls in the optimum way, minimizing the passenger waiting
time.
•
The elevators are configured as the master and slave ones. When they have the same
response conditions, the system instructs the master or slave to respond a call based
on the random function.
•
The parallel/group control function considers the call response time, elevator use
efficiency, and in-car passenger waiting time. It avoids use ratio imbalance of elevators,
implements coordination between elevators to respond to hall calls and improves the
elevator use efficiency.
The following part describes the parallel control and group control in detail.
1) Parallel control
•
Parameter setting
To use parallel control, connect the CAN2+ and CAN2- terminals of CN6 on the
controller to respectively the corresponding terminals on the other one.
The following table lists the parameter setting of parallel control.
Table 5-6 Parameter setting of parallel control
Function Code
Parameter Name
Setting Range
Setting in Parallel Control
Fd-00
Number of elevators in
parallel/group mode
1–2
1–2
Fd-01
Elevator No.
1–2
1: master elevator
2: slave elevator
•
Address Setting of Physical Floors
Physical floor, relative to the NICE control system, is defined by the installation position
of the leveling plate.
The floor (such as the ground floor) at which the lowest leveling plate is installed
corresponds to physical floor 1.
The top physical floor is the accumulative number of the leveling plates.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......