NICE7000 User Manual 6 Function Code Table
- 115 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
F6-19
Fire emergency
function selection 3
Bit0: Nearest call mode
Bit1: First call mode
Bit2: Last call mode
Bit3 to Bit4: Reserved
Bit5: Call registered by holding
down button
Bit6: Closing door by holding
down the door close button
Bit7: Reserved
Bit8: Door close at car call active
Bit9: Reserved
Bit10: Reserved
Bit11: Automatic door open at
arrival
Bit12: Reserved
Bit13: Reserved
Bit14: Opening door by holding
down the door open button
Bit15: Automatic door open after
arrival at fire emergency floor
17156
-
★
F6-22
Elevator lock start
time
00.00–23.59
00.00
HH.MM
☆
F6-23
Elevator lock end
time
00.00–23.59
00.00
HH.MM
☆
F6-24
Attendant function
selection
Bit0: Calls cancelled after entering
attendant state
Bit1: Not responding to hall calls
Bit2: Attendant/Automatic state
switchover
Bit3: Door close at jogging
Bit4: Automatic door close
Bit5: Buzzer tweeting at intervals
in attendant state
0
-
★
F6-25
Attendant/
Automatic
switchover time
0–200
0
s
★
F6-26
Emergency
evacuation time
limit
30–600
45
s
★
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......