NICE7000 User Manual Introduction
- 7 -
Fault data recording
The system automatically records detailed information of faults, which
helps improve the efficiency of maintenance and repair.
Inspection-related Functions
Simple maintenance
keypad
The 3-button keypad on the MCB provides the functions such as
commissioning the running floors and door open/close.
Easy setting for
commissioning and
maintenance
Commissioning and maintenance can be carried out only with easy
setting:
motor auto-tuning, slow-down switch detection and shaft detection,
automatic detection of elevator states, abnormality record, and periodic
self-check
Operation box
commissioning
The operation panel can be connected to the system in the car for
elevator commissioning, which improves the commissioning efficiency.
Shaft auto-tuning
Shaft auto-tuning is required before first-time automatic running. During
shaft auto-tuning, the elevator runs from the bottom floor to the top floor
at the inspection speed and automatically records all position signals in
the shaft.
User-defined
parameter display
You can view the parameters that are modified and different from the
default setting.
Inspection function
selection
The system provides multiple inspection functions for users to select.
Inspection running
After entering the inspection state, the system cancels automatic running
and related operations. You can press the up or down call button to make
the elevator jog at the inspection speed.
Motor auto-tuning
With simple parameter setting, the system can obtain the motor
parameters no matter whether the motor is with-load or without load.
Inertia identification
The system automatically identifies the elevator inertia at startup and
produces compensation, achieving smooth running.
Floor position
intelligent correction
Every time the elevator runs to the terminal floor, the system automatically
checks and corrects the car position information based on slow-down
switch 1, and eliminates over travel top terminal or bottom terminal with
use of the slow-down switches.
Dual-speed for
inspection
Considering inaccurate running control at high inspection speed but long
running time at low inspection speed, the system provides the dual-speed
curve for inspection, which greatly improves the efficiency at inspection.
Indication state test
Whether indications of system states can be tested.
Test function
selection
The system provides multiple test functions for users to select, improving
test, acceptance, and maintenance efficiency.
Test running
The test running includes the fatigue test of a new elevator, car call floor
test, hall call test, and tests such as hall call response forbidden, door
open/close forbidden, terminal floor limit switch shielded, and overload
signal shielded.
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......